Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 198
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38668934

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) has emerged as a physiological alternative pacing strategy to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). We aimed to assess the impact of LBBAP vs. BIVP on all-cause mortality and heart failure (HF)-related hospitalization in patients undergoing CRT. METHODS: Studies comparing LBBAP and BIVP for CRT in patients with HF with reduced left ventricular ejection fraction (LVEF) were included. The coprimary outcomes were all-cause mortality and HF-related hospitalization. Secondary outcomes included procedural and fluoroscopy time, change in QRS duration, and change in LVEF. RESULTS: Thirteen studies (12 observational and 1 RCT, n = 3239; LBBAP = 1338 and BIVP = 1901) with a mean follow-up duration of 25.8 months were included. Compared to BIVP, LBBAP was associated with a significant absolute risk reduction of 3.2% in all-cause mortality (9.3% vs 12.5%, RR 0.7, 95% CI 0.57-0.86, p < 0.001) and an 8.2% reduction in HF-related hospitalization (11.3% vs 19.5%, RR 0.6, 95% CI 0.5-0.71, p < 0.00001). LBBAP also resulted in reductions in procedural time (mean weighted difference- 23.2 min, 95% CI - 42.9 to - 3.6, p = 0.02) and fluoroscopy time (- 8.6 min, 95% CI - 12.5 to - 4.7, p < 0.001) as well as a significant reduction in QRS duration (mean weighted difference:- 25.3 ms, 95% CI - 30.9 to - 19.8, p < 0.00001) and a greater improvement in LVEF of 5.1% (95% CI 4.4-5.8, p < 0.001) compared to BIVP in the studies that reported these outcomes. CONCLUSION: In this meta-analysis, LBBAP was associated with a significant reduction in all-cause mortality as well as HF-related hospitalization when compared to BIVP. Additional data from large RCTs is warranted to corroborate these promising findings.

4.
Heart Rhythm O2 ; 5(1): 24-33, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38312200

RESUMEN

Background: Catheter ablation of premature ventricular complexes (PVCs) and ventricular tachycardia (VT) from the left ventricular summit (LVS) may require advanced ablation techniques. Bipolar ablation from the coronary veins and adjacent endocardial structures can be effective for refractory LVS arrhythmias. Objective: The aim of this study was to investigate the outcomes of bipolar ablation performed between the coronary venous system and adjacent endocardial left ventricular outflow tract (LVOT) or right ventricular outflow tract (RVOT). Methods: This multicenter study included consecutive patients with LVS PVC/VT who underwent bipolar ablation between the anterior interventricular vein (AIV) or great cardiac vein (GCV) and the endocardial LVOT/RVOT after failed unipolar ablation. Ablation was started with powers of 10-20 W and uptitrated to achieve an impedance drop of at least 10%. Angiography was performed in all cases to confirm a safe distance (>5 mm) of the catheter from the major coronary arteries. Results: Between 2013 and 2023, bipolar radiofrequency ablation between the AIV/GCV and the adjacent LVOT/RVOT was attempted in 20 patients (4 female; age 57 ± 16 years). Unipolar ablation from sites of early activation (AIV/GCV, LVOT, aortic cusps, RVOT) failed to effectively suppress the PVC/VT in all subjects. Bipolar ablation was delivered with a maximum power of 30 ± 8 W and total duration of 238 ± 217 s and led to acute PVC/VT elimination in all patients. No procedural-related complications occurred. Over a follow-up period of 30 ± 24 months, the freedom from arrhythmia recurrence was 85% (1 recurrence in the VT group and 2 in the PVC group). PVC burden was reduced from 22% ± 10% to 4% ± 8% (P <.001). Conclusion: In cases of LVS PVC/VT refractory to unipolar ablation, bipolar ablation between the coronary venous system and adjacent endocardial LVOT/RVOT is safe and effective if careful titration of power and intraprocedural angiography are performed to ensure a safe distance from the coronary arteries.

6.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927196

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Resultado del Tratamiento
7.
JACC Clin Electrophysiol ; 10(2): 295-305, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38127008

RESUMEN

BACKGROUND: Left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) are considered to be acceptable as LBBAP strategies. Differences in clinical outcomes between LBBP and LVSP are yet to be determined. OBJECTIVES: The purpose of this study was to compare the outcomes of LBBP vs LVSP vs BIVP for CRT. METHODS: In this prospective multicenter observational study, LBBP was compared with LVSP and BIVP in patients undergoing CRT. The primary composite outcome was freedom from heart failure (HF)-related hospitalization and all-cause mortality. Secondary outcomes included individual components of the primary outcome, postprocedural NYHA functional class, and electrocardiographic and echocardiographic parameters. RESULTS: A total of 415 patients were included (LBBP: n = 141; LVSP: n = 31; BIVP: n = 243), with a median follow-up of 399 days (Q1-Q3: 249.5-554.8 days). Freedom from the primary composite outcomes was 76.6% in the LBBP group and 48.4% in the LVSP group (HR: 1.37; 95% CI: 1.143-1.649; P = 0.001), driven by a 31.4% absolute increase in freedom from HF-related hospitalizations (83% vs 51.6%; HR: 3.55; 95% CI: 1.856-6.791; P < 0.001) without differences in all-cause mortality. LBBP was also associated with a higher freedom from the primary composite outcome compared with BIVP (HR: 1.43; 95% CI: 1.175-1.730; P < 0.001), with no difference between LVSP and BIVP. CONCLUSIONS: In patients undergoing CRT, LBBP was associated with improved outcomes compared with LVSP and BIVP, while outcomes between BIVP and LVSP are similar.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Estudios Prospectivos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos , Electrocardiografía
10.
JACC Clin Electrophysiol ; 9(12): 2573-2583, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37804258

RESUMEN

BACKGROUND: High-power short-duration (HPSD) radiofrequency ablation of atrial fibrillation (AF) increases first-pass pulmonary vein isolation (PVI) and freedom from atrial arrhythmias while decreasing procedural time. However, the optimal power setting in terms of safety and efficacy has not been determined. OBJECTIVES: This study compared the procedural characteristics and clinical outcomes of 50-W vs 40-W during HPSD ablation of paroxysmal AF. METHODS: Patients from the REAL-AF prospective multicenter registry (Real-World Experience of Catheter Ablation for Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation) undergoing HPSD ablation of paroxysmal AF, either using 50-W or 40-W, were included. The primary efficacy outcome was freedom from all-atrial arrhythmias. The primary safety outcome was the occurrence of any procedural complication at 12 months. Secondary outcomes included procedural characteristics, AF-related symptoms, and the occurrence of transient ischemic attack or stroke at 12 months. RESULTS: A total of 383 patients were included. Freedom from all-atrial arrhythmias at 12 months was 80.7% in the 50-W group and 77.3% in the 40-W group (Log-rank P = 0.387). The primary safety outcome occurred in 3.7% of patients in the 50-W group vs 2.8% in the 40-W group (P = 0.646). The 50-W group had a higher rate of first-pass PVI (82.3% vs 76.2%; P = 0.040) as well as shorter procedural (67 minutes [IQR: 54-87.5 minutes] vs 93 minutes [IQR: 80.5-111 minutes]; P < 0.001) and radiofrequency ablation times (15 minutes [IQR: 11.4-20 minutes] vs 27 minutes [IQR: 21.5-34.6 minutes]; P < 0.001) than the 40-W group. CONCLUSIONS: There was no significant difference in freedom from all-atrial arrhythmias or procedural safety outcomes between 50-W and 40-W during HPSD ablation of paroxysmal AF. The use of 50-W was associated with a higher rate of first-pass PVI as well as shorter procedural times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Humanos , Estudios Prospectivos , Recurrencia Local de Neoplasia/etiología , Factores de Tiempo , Ablación por Catéter/efectos adversos
12.
JACC Clin Electrophysiol ; 9(11): 2342-2346, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37737777

RESUMEN

The authors describe 3 patients presenting with cardiac sarcoidosis (CS) flare and ventricular tachycardia (VT) storm following infection with severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2), the causative agent of COVID-19. COVID-19-related cardiac manifestations can vary and include arrythmias, myocarditis, and exacerbation of underlying cardiovascular disease. The exact mechanism of myocardial involvement is not clear but may include abnormal host immune response and direct myocardial injury, thereby predisposing to enhanced arrhythmic risk. Arrhythmias account for 20% of COVID-19-related complications with ventricular arrythmias occurring in 5.9% of cases. Further studies are needed to better understand mechanisms underlying the intersection between COVID-19 infection and inflammatory cardiomyopathies.


Asunto(s)
COVID-19 , Cardiomiopatías , Miocarditis , Sarcoidosis , Taquicardia Ventricular , Humanos , COVID-19/complicaciones , Cardiomiopatías/complicaciones , SARS-CoV-2 , Sarcoidosis/complicaciones , Arritmias Cardíacas/complicaciones
13.
Heart Rhythm ; 20(12): 1674-1681, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37598986

RESUMEN

BACKGROUND: Infection is the most dreaded complication of cardiac implantable electronic devices (CIEDs), particularly in patients undergoing high-risk procedures (eg, generator change, device upgrade, lead/pocket revision). OBJECTIVE: The purpose of this study was to describe the impact of chlorhexidine gluconate (CHG) pocket lavage in high-risk procedures. METHODS: Patients from a prospective multicenter registry undergoing high-risk procedures were included. CHG lavage was performed by irrigating the generator pocket with 20 cc of 2% CHG without alcohol followed by and normal saline (NS) irrigation. Only NS irrigation was performed in the comparison group. The primary efficacy outcome was CIED-related infection at 12 months. The primary safety outcome was any CHG-associated adverse event. The secondary outcome was CIED infection during long-term follow-up. Propensity score matching (PSM) analysis was performed for the primary efficacy outcome. RESULTS: A total of 1504 patients were included. At 12-month follow-up, the primary efficacy outcome occurred in 4 of 904 CHG (0.4%) and 14 of 600 NS (2.3%) subjects (log-rank P = .005). On multivariate analysis, the use of CHG irrigation was associated with a lower risk of infection at 1-year follow-up (Cox proportional hazard ratio [HR] 0.138; 95% confidence interval [CI] 0.04-0.45; P = .001). This effect persisted during long-term follow-up. PSM demonstrated a significant reduction in CIED-related infection for the CHG group (0.2% vs 2.5%; Cox proportional HR 0.08; 95% CI 0.01-0.59; P = .014). No adverse events were associated with the use of CHG. CONCLUSION: CHG lavage during high-risk procedures was associated with a reduction in CIED-related infections without any adverse events reported. The benefits of CHG lavage were observed even during long-term follow up and in PSM analysis.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Desfibriladores Implantables/efectos adversos , Cardiopatías/etiología , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/prevención & control , Irrigación Terapéutica
14.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1487-1499, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37486280

RESUMEN

BACKGROUND: Epicardial access (EA) has emerged as an increasingly important approach for the treatment of ventricular arrhythmias and to perform other interventional cardiology procedures. EA is frequently underutilized because the current approach is challenging and carries a high risk of life-threatening complications. OBJECTIVE: The purpose of this study was to determine the efficacy and safety of the SAFER (Sustained Apnea for Epicardial Access With Right Ventriculography) epicardial approach. METHODS: Consecutive patients who underwent EA with the SAFER technique were included in this multicenter study. The primary efficacy outcome was the successful achievement of EA. The primary safety outcomes included right ventricular (RV) perforation, major hemorrhagic pericardial effusion (HPE), and bleeding requiring surgical intervention. Secondary outcomes included procedural characteristics and any complications. Our results were compared with those from previous studies describing other EA techniques to assess differences in outcomes. RESULTS: A total of 105 patients undergoing EA with the SAFER approach from June 2021 to February 2023 were included. EA was used for ventricular tachycardia ablation in 98 patients (93.4%), left atrial appendage closure in 6 patients (5.7%), and phrenic nerve displacement in 1 patient (0.9%). EA was successful in all subjects (100%). The median time to EA was 7 minutes (IQR: 5-14 minutes). No cases of RV perforation, HPE, or need of surgical intervention were observed in this cohort. Comparing our results with previous studies about EA, the SAFER epicardial approach resulted in a significant reduction in major pericardial bleeding. CONCLUSIONS: The SAFER epicardial approach is a simple, efficient, effective, and low-cost technique easily reproducible across multiple centers. It is associated with lower complication rates than previously reported techniques for EA.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Lesiones Cardíacas , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Apnea , Arritmias Cardíacas , Pericardio/diagnóstico por imagen , Pericardio/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Hemorragia
15.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1404-1408, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37227346

RESUMEN

The authors sought to evaluate a method for improving radiofrequency (RF) lesion durability using doxorubicin encased in heat-sensitive liposomes (HSL-dox). Using a porcine model, RF ablations were performed in the right atrium after systemic infusion of either HSL-dox or saline control given immediately before mapping and ablation. Lesion geometry was measured with voltage mapping immediately postablation and after 2 weeks of survival. After 2 weeks, lesions demonstrated less regression in scar area in HSL-dox-exposed animals compared with control animals. We demonstrate improved RF lesion durability in animals treated with HSL-dox, and the cardiotoxic effect was more pronounced after RF applications with higher power and longer duration.


Asunto(s)
Calor , Liposomas , Porcinos , Animales , Miocardio , Doxorrubicina/uso terapéutico , Atrios Cardíacos
16.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1719-1729, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37227359

RESUMEN

BACKGROUND: Multiple cardiac sarcoidosis (CS) diagnostic schemes have been published. OBJECTIVES: This study aims to evaluate the association of different CS diagnostic schemes with adverse outcomes. The diagnostic schemes evaluated were 1993, 2006, and 2017 Japanese criteria and the 2014 Heart Rhythm Society criteria. METHODS: Data were collected from the Cardiac Sarcoidosis Consortium, an international registry of CS patients. Outcome events were any of the following: all-cause mortality, left ventricular assist device placement, heart transplantation, and appropriate implantable cardioverter-defibrillator therapy. Logistic regression analysis evaluated the association of outcomes with each CS diagnostic scheme. RESULTS: A total of 587 subjects met the following criteria: 1993 Japanese (n = 310, 52.8%), 2006 Japanese (n = 312, 53.2%), 2014 Heart Rhythm Society (n = 480, 81.8%), and 2017 Japanese (n = 112, 19.1%). Patients who met the 1993 criteria were more likely to experience an event than patients who did not (n = 109 of 310, 35.2% vs n = 59 of 277, 21.3%; OR: 2.00; 95% CI: 1.38-2.90; P < 0.001). Similarly, patients who met the 2006 criteria were more likely to have an event than patients who did not (n = 116 of 312, 37.2% vs n = 52 of 275, 18.9%; OR: 2.54; 95% CI: 1.74-3.71; P < 0.001). There was no statistically significant association between the occurrence of an event and whether a patient met the 2014 or the 2017 criteria (OR: 1.39; 95% CI: 0.85-2.27; P = 0.18 or OR: 1.51; 95% CI: 0.97-2.33; P = 0.067, respectively). CONCLUSIONS: CS patients who met the 1993 and the 2006 criteria had higher odds of adverse clinical outcomes. Future research is needed to prospectively evaluate existing diagnostic schemes and develop new risk models for this complex disease.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Trasplante de Corazón , Miocarditis , Sarcoidosis , Humanos , Sarcoidosis/diagnóstico , Sarcoidosis/epidemiología , Sarcoidosis/complicaciones , Desfibriladores Implantables/efectos adversos
17.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1568-1581, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37212761

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) for cardiac resynchronization therapy (CRT) is an alternative to biventricular pacing (BiVp). OBJECTIVES: The purpose of this study was to compare the outcomes between LBBAP and BiVp as an initial implant strategy for CRT. METHODS: In this prospective multicenter, observational, nonrandomized study, first-time CRT implant recipients with LBBAP or BiVp were included. The primary efficacy outcome was a composite of heart failure (HF)-related hospitalization and all-cause mortality. The primary safety outcomes were acute and long-term complications. Secondary outcomes included postprocedural New York Heart Association functional class and electrocardiographic and echocardiographic parameters. RESULTS: A total of 371 patients (median follow-up of 340 days [IQR: 206-477 days]) were included. The primary efficacy outcome occurred in 24.2% in the LBBAP vs 42.4% in the BiVp (HR: 0.621 [95% CI: 0.415-0.93]; P = 0.021) group, driven by a reduction in HF-related hospitalizations (22.6% vs 39.5%; HR: 0.607 [95% CI: 0.397-0.927]; P = 0.021) without significant difference in all-cause mortality (5.5% vs 11.9%; P = 0.19) or differences in long-term complications (LBBAP: 9.4% vs BiVp: 15.2%; P = 0.146). LBBAP resulted in shorter procedural (95 minutes [IQR: 65-120 minutes] vs 129 minutes [IQR: 103-162 minutes]; P < 0.001) and fluoroscopy times (12 minutes [IQR: 7.4-21.1 minutes] vs 21.7 minutes [IQR: 14.3-30 minutes]; P < 0.001), shorter QRS duration (123.7 ± 18 milliseconds vs 149.3 ± 29.1 milliseconds; P < 0.001), and higher postprocedural left ventricular ejection fraction (34.1% ± 12.5% vs 31.4% ± 10.8%; P = 0.041). CONCLUSIONS: LBBAP as an initial CRT strategy resulted in a lower risk of HF-related hospitalizations compared to BiVp. A reduction in procedural and fluoroscopy times, shorter paced QRS duration, and improvements in left ventricular ejection fraction compared with BiVp were observed.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Volumen Sistólico , Estudios Prospectivos , Función Ventricular Izquierda , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia
19.
Card Electrophysiol Clin ; 15(1): 57-62, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36774137

RESUMEN

Challenging anatomic and morphologic conditions of the left ventricular (LV) summit architecture and its surrounding sites may prevent sufficient heating of the targeted area during standard radiofrequency catheter ablation. Bipolar ablation can result in higher likelihood of efficacy for ablation of LV summit arrhythmias from inaccessible regions and increase the chance of achieving a transmural lesion. In this review, the authors describe the present approaches for bipolar ablation of the LV summit arrhythmias refractory to standard approaches.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Electrocardiografía , Resultado del Tratamiento , Ventrículos Cardíacos/cirugía , Arritmias Cardíacas/cirugía
20.
J Cardiovasc Electrophysiol ; 34(4): 918-927, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36852908

RESUMEN

INTRODUCTION: The association between ambient circulating environments (CEs) and ablation lesions has been largely underexplored. METHODS: Viable bovine myocardium was placed in a saline bath in an ex vivo endocardial model. Radiofrequency (RF) ablation was performed using three different ablation catheters: 3.5 mm open irrigated (OI), 4, and 8 mm. Variable flow rates of surrounding bath fluids were applied to simulate standard flow, high flow, and no flow. For in vivo epicardial ablation, 24 rats underwent a single OI ablation and performed with circulating saline (30 ml/min; n = 12), versus those immersed in saline without circulation (n = 12). RESULTS: High flow reduced ablation lesion volumes for all three catheters. In no-flow endocardial CE, both 4 mm and OI catheters produced smaller lesions compared with standard flow. However, the 8 mm catheter produced the largest lesions in a no-flow CE. Ablation performed in an in vivo model with CE resulted in smaller lesions compared with ablation performed in a no-flow environment. No statistically significant differences in steam pops were found among the groups. CONCLUSION: A higher endocardial CE flow can decrease RF effectiveness. Cardiac tissue subjected to no endocardial CE flow may also limit RF for 4 mm catheters, but not for OI catheters; these findings may have implications for RF ablation safety and efficacy, especially in the epicardial space without circulating fluid or in the endocardium under varying flow conditions.


Asunto(s)
Corazón , Miocardio , Animales , Bovinos , Ratas , Diseño de Equipo , Miocardio/patología , Endocardio/cirugía , Catéteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...